Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 94
Filtrar
1.
Surg Endosc ; 37(10): 7658-7666, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37495849

RESUMO

BACKGROUND: Capsule endoscopy (CE) is the first-choice exploration in case of overt small bowel bleeding (SBB). An early CE is known to increase diagnostic yield, but long reading times may delay therapeutics. The study evaluates the diagnostic performance of the artificial intelligence tool TOP100 in patients with overt SBB undergoing early CE with Pillcam SB3. METHODS: Patients who underwent early CE (up to 14 days from the bleeding episode) for suspected overt SBB were included. One experienced endoscopist prospectively performed standard reading (SR) and a second blind experienced endoscopist performed a TOP100-based reading (TR). The primary endpoint was TR diagnostic accuracy for lesions with high bleeding potential (P2). RESULTS: A total of 111 patients were analyzed. The most common clinical presentation was melena (64%). CE showed angiodysplasias in 40.5% of patients (45/111). In per-patient analysis, TR showed a sensitivity of 90.48% (95% CI 82.09-95.80), specificity of 100% (95% CI 87.23-100) with a PPV of 100% (95% CI 94.01-100), NPV of 77.14% (95% CI 63.58-86.71) and diagnostic accuracy of 92.79 (86.29-96.84). At multivariate analysis, adequate intestinal cleansing was the only independent predictor of concordance between TR and SR (OR 2.909, p = 0.019). The median reading time for SR and TR was 23 min (18.0-26.8) and 1.9 min (range 1.7-2.1), respectively (p < 0.001). CONCLUSIONS: TOP100 provides a fast-reading mode for early CE in case of overt small bowel bleeding. It identifies most patients with active bleeding and angiodysplasias, aiding in the prioritization of therapeutic procedures. However, its accuracy in detecting ulcers, varices and P1 lesions seems insufficient.


Assuntos
Angiodisplasia , Endoscopia por Cápsula , Humanos , Inteligência Artificial , Hemorragia Gastrointestinal/diagnóstico por imagem , Hemorragia Gastrointestinal/etiologia , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/patologia , Angiodisplasia/diagnóstico , Angiodisplasia/diagnóstico por imagem
2.
J Environ Manage ; 330: 117099, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36621310

RESUMO

The proclamation of the sustainable development goals is driving companies to implement protective measures that favour the environment, thereby occupying a strategic place in the creation of green product innovation (GPI). This new management paradigm could be impacting capabilities, techniques, technologies, efficient energy use and green-oriented production policies and systems. Therefore, one of the challenges is to configure green production capabilities (GPC) coordinated with the technology dimension (TECH) because the design of ecological products and their manufacture requires the backup of capabilities and the possible support of green technology. To this effect, this article aims to establish the impact of the association of GPC and TECH on organisational performance. To do so, we test whether the adoption and high implementation of GPC and TECH affect environmental and financial performance. Empirical evidence is supported by the European Manufacturing Survey (EMS), using a sample of 1018 manufacturing companies from seven European countries. Our results show that the adoption of GPC and TECH and their high levels of implementation have a significant impact on environmental and financial performance. Regarding the association between the implementation of GPC and TECH, its contribution to environmental performance but not financial performance is evidenced. Furthermore, at high levels of implementation of this association, there is no significant effect on either environmental or financial performance. These findings drive theoretical and practical implications and provide opportunities for academics, managers and government bodies.


Assuntos
Comércio , Tecnologia , Governo , Organizações , Europa (Continente) , China
3.
Dig Dis Sci ; 68(4): 1447-1454, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36104534

RESUMO

BACKGROUND: Motorized Spiral Enteroscopy (MSE) reduces procedure time and increases insertion depth into the small bowel; however, there is scarce evidence on factors affecting MSE efficacy. AIMS: To evaluate diagnostic yield and adverse events of MSE including patients with prior major abdominal surgery. METHODS: A prospective observational study was conducted on patients undergoing MSE from June 2019 to December 2021. Demographic characteristics, procedure time, depth of maximum insertion (DMI), technical success, diagnostic yield, and adverse events were collected. RESULTS: Seventy-four anterograde (54.4%) and 62 retrograde (45.6%) enteroscopies were performed in 117 patients (64 males, median age 67 years). Fifty patients (42.7%) had prior major abdominal surgery. Technical success was 91.9% for anterograde and 90.3% for retrograde route. Diagnostic yield was 71.6% and 61.3%, respectively. The median DMI was 415 cm (264-585) for anterograde and 120 cm (37-225) for retrograde enteroscopy. In patients with prior major abdominal surgery, MSE showed significantly longer small bowel insertion time (38 vs 29 min, p = 0.004), with similar diagnostic yield (61 vs 71.4%, p = 0.201) and DMI (315 vs 204 cm, p = 0.226). The overall adverse event rate was 10.3% (SAE 1.5%), with no differences related to prior abdominal surgery (p = 0.598). Patients with prior surgeries directly involving the gastrointestinal tract showed lower DMI (189 vs 374 cm, p = 0.019) with equal exploration time (37.5 vs 38 min, p = 0.642) compared to those with other abdominal surgeries. CONCLUSIONS: MSE is effective and safe in patients with major abdominal surgery, although longer procedure times were observed. A lower depth of insertion was detected in patients with gastrointestinal surgery.


Assuntos
Enteropatias , Laparoscopia , Masculino , Humanos , Idoso , Enteropatias/diagnóstico , Endoscopia Gastrointestinal/efeitos adversos , Endoscopia Gastrointestinal/métodos , Estudos Prospectivos , Intestino Delgado/cirurgia , Enteroscopia de Duplo Balão/métodos
4.
Gastroenterol Hepatol ; 46(5): 360-368, 2023 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36179948

RESUMO

BACKGROUND: Barrett's esophagus (BE) is an entity with a known histological progression to malignancy. The insulin-like growth factor (IGF) system is involved in the carcinogenesis through obesity-related mechanisms that include IGF and it has been associated with several types of cancer. OBJECTIVES: To evaluate the serological levels of IGF-1 and IGFBP-3 in patients with BE and esophageal adenocarcinoma. PATIENTS AND METHODS: Prospective study of patients with BE and esophageal adenocarcinoma who underwent upper endoscopy between September 2012 and December 2015. A baseline determination of IGF-1 and IGFBP-3 was performed. We included a control group of patients without BE. RESULTS: One hundred sixteen patients were included: 36 controls, 62 with BE (42 without dysplasia and 20 with dysplasia) and 18 with adenocarcinoma. IGF-1 and IGF-1/IGFBP-3 molar ratio showed a progression to high levels in BE and adenocarcinoma than in controls (IGF-1: 135.55±66.07ng/ml, 148.33±81.5ng/ml, 108.19±46.69ng/ml, respectively; P=.049) (molar ratio: 0.23±0.91, 0.29±0.11, 0.19±0.06, respectively; P=.001), without differences between the histological types of BE. Fifty-four out of the 65 patients with BE were followed up (median of 58.50 months, range 12-113) and 11 of them (20.4%) presented progression to low-grade dysplasia (n=8) or high-grade dysplasia/adenocarcinoma (n=3), without differences in the IGF system compared with patients without progression. CONCLUSIONS: Patients with BE and esophageal adenocarcinoma have changes in the IGF system although the serological levels of IGF-1 and IGFBP-3 do not correlate with histological progression of BE.


Assuntos
Adenocarcinoma , Esôfago de Barrett , Neoplasias Esofágicas , Humanos , Esôfago de Barrett/metabolismo , Esôfago de Barrett/patologia , Estudos Longitudinais , Proteína 3 de Ligação a Fator de Crescimento Semelhante à Insulina , Fator de Crescimento Insulin-Like I/metabolismo , Estudos Prospectivos , Progressão da Doença , Neoplasias Esofágicas/patologia , Adenocarcinoma/patologia
5.
AIDS Res Hum Retroviruses ; 39(5): 211-221, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36416229

RESUMO

Most of the studies using the colorectal tissue explants challenge model have been conducted after one single dose and before reaching a steady state. We consider that longer exposure as in 28-day postexposure prophylaxis (PEP) course and in an at-risk setting, such as after a sexual risk exposure to HIV could give us valuable information about these drugs. In a substudy we assessed pharmacokinetics, changes on immune system and ex-vivo rectal mucosal susceptibility to HIV-1 infection after taking maraviroc (MVC), raltegravir (RAL), and ritonavir-boosted lopinavir (LPV/r) PEP-based regimens in 30 men who have sex with men. Participants received 28 days of twice-daily MVC (n = 11), RAL (n = 10) or LPV/r (n = 9) all with tenofovir/emtricitabine (TDF/FTC) backbone. Blood, rectal fluid, and rectal tissue samples were collected at days 7, 28, and 90 after starting PEP. The samples obtained at day 90 were considered baseline. All studied antiretrovirals were quantifiable at 7 and 28 days in all tissues. Activation markers were increased in CD4 mucosal mononuclear cells (MMCs) after 28 days of MVC: CD38 + 68.5 versus 85.1, p = .008 and CD38+DR +16.1 versus 26.7, p = .008. Exposure to MVC at both endpoints (7 and 28 days) was associated with significant suppression of HIV-1BAL (p = .005 and p = .028), but we did not observe this effect with RAL or LPV/r. Merging together changes in MMC in all arms, we found a positive correlation in the CD8 T cell lineage between the infectivity at day 7 and activation (CD38+ r = 0.43, p = .025, DR + r = 0.547, p = .003 and 38+DR+ r = 0.526, p = .05), senescence (CD57+CD28- r = 0.479, p = .012), naive cells (RA+CCR7+ r = 0.484, p = .01), and CCR5 expression (r = 0.593, p = .001). We conclude that MVC in combination with TDF/FTC was associated with viral suppression in rectal explants and that overall ex-vivo HIV infectivity correlated with activation and senescence in CD8 MMCs.


Assuntos
Fármacos Anti-HIV , Infecções por HIV , Minorias Sexuais e de Gênero , Masculino , Humanos , Maraviroc , Raltegravir Potássico/uso terapêutico , Lopinavir/uso terapêutico , Infecções por HIV/tratamento farmacológico , Infecções por HIV/prevenção & controle , Fármacos Anti-HIV/uso terapêutico , Homossexualidade Masculina , Emtricitabina/uso terapêutico , Ritonavir/uso terapêutico , Profilaxia Pós-Exposição
6.
Diagnostics (Basel) ; 12(9)2022 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-36140627

RESUMO

(1) Background: Fecal calprotectin (FC) correlates well with colonic inflammatory activity of Crohn's disease (CD); data about relation of FC and small bowel (SB) lesions are still contradictory. The main aim was to analyze the relationship between FC levels and SB inflammatory activity in patients with established or suspected Crohn's disease, assessed by small bowel capsule endoscopy (SBCE) or magnetic resonance enterography (MRE). (2) Methods: Two cohorts of patients were included: 1. Prospective data were collected from patients with established or suspected CD who underwent SBCE and FC (Cohort A); 2. A retrospective cohort of patients who underwent MRE and FC determination (Cohort B). Different cutoffs for FC were tested in both cohorts. (3) Results: 83 patients were included and 66 were finally analyzed. A total of 69.6% had SB lesions seen by SBCE (n = 25) or MRE (n = 21). FC mean levels were 605.74 + 607.07 µg/g (IQ range: 99.00−878.75), being significantly higher in patients with SB lesions compared to patients without lesions (735.91 + 639.70 µg/g (IQ range: 107.75−1366.25) vs. 306.35 + 395.26 µg/g (IQ range: 78.25−411.0), p < 0.005). For cohort A, 25 out of 35 patients had SB lesions and a significant correlation between Lewis Score and FC levels was achieved (R2: 0.34; p = 0.04). FC sensitivity (S), specificity (E), positive predictive value (PPV), and negative predictive values (NPV) for predicting SB lesions were 80%, 50%, 80%, and 50%, respectively, for FC > 100 µg/g. For cohort B, inflammatory SB activity, measured by MaRIA score, was detected in 21 out of 31 patients (67.7%). Patients with positive findings in MRE had significantly higher values of FC than those with no lesions (944.9 + 672.1 µg/g vs. 221 + 212.2 µg/g, p < 0.05). S, E, PPV, and NPV of FC were 89%, 50%, 77.2%, and 71.4% for FC levels > 100 µg/g. The higher sensitivity and specificity of the FC levels for the detection of SB lesions with SBCE and MRE was obtained for an FC cutoff >265 µg/g and >430 µg/g, respectively. (4) Conclusions: FC has a good correlation with the presence of SB lesions, assessed by SBCE and MRE, in patients with established or suspected Crohn's disease. However, the ideal cutoff is here proven to be higher than previously reported. Multicenter and large prospective studies are needed in order to establish definitive FC cutoff levels.

7.
J Clin Med ; 11(8)2022 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-35456274

RESUMO

OBJECTIVES: The role of colorectal neoplasms (CRN) as a common potential source of recurrent Streptococcus gallolyticus subsp. gallolyticus (SGG) and Enterococcus faecalis (EF) endocarditis remains unstudied. We aimed to investigate what proportion of episodes of recurrent endocarditis are caused by a succession of SGG and EF, or vice versa, and to assess the role of a colonic source in such recurrent episodes. METHODS: we conducted a retrospective analysis of two prospective endocarditis cohorts (1979-2019) from two Spanish hospitals, providing descriptive analyses of the major features of the endocarditis episodes, colonoscopy findings, and histologic results. RESULTS: among 1552 IE episodes, 204 (13.1%) were caused by EF and 197 (12.7%) by SGG, respectively. There were 155 episodes (10%) of recurrent IE, 20 of which (12.9%) were due to a succession of SGG/EF IE in 10 patients (the first episode caused by SGG in eight cases, and by EF in two cases). The median follow-up was 86 (interquartile range 34-156) months. In 8/10 initial episodes, the causative microorganism was SGG, and all patients were diagnosed with CRN either during the initial episode or during follow-up. During the second episode of IE or follow-up, colonoscopies revealed CRN in six patients. CONCLUSIONS: There seems to be an association between SGG and EF in recurrent endocarditis that warrants further investigation. Our findings reinforce the need for systematically performing colonoscopy in the event of endocarditis caused by both microorganisms.

8.
Dig Dis ; 40(3): 376-384, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34348294

RESUMO

BACKGROUND: Regular arrangement of collecting venules (RAC) in gastric mucosa accurately identifies patients without Helicobacter pylori (H pylori) infection. The aim of our study was to evaluate the reproducibility of RAC using white light endoscopy without magnification, in a European country, and to assess the impact of proton pump inhibitors (PPIs). METHODS: A multicenter prospective study with image capture of the distal lesser gastric curvature and gastric biopsies was performed. The presence of starfish-like minute points regularly distributed throughout lesser curvature was considered as RAC positive (RAC+). A set of 20 images was used for the training phase and inter and intra-observer agreements were calculated. RESULTS: 174 patients were included and 85 (48.9%) were taking PPIs. Kappa values for interobserver and intra-observer agreements were substantial (0.786) and excellent (0.906), respectively. H. pylori infection was diagnosed in 29 patients (16.7%): 10/85 with PPIs and 19/89 without PPIs (11.8% vs. 21.3%; p = 0.09). All RAC + patients were free of H. pylori infection, with a sensitivity and negative predictive value of 100%, regardless of PPI intake. CONCLUSION: The endoscopic diagnosis of H. pylori by RAC is an easy-to-learn and highly reproducible technique, even with PPI intake. Our results warrant RAC as a real-time diagnostic method for H. pylori-negative infection in Western practice.


Assuntos
Infecções por Helicobacter , Helicobacter pylori , Mucosa Gástrica/patologia , Gastroscopia/métodos , Infecções por Helicobacter/diagnóstico , Humanos , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Vênulas/patologia
9.
Gastroenterol. hepatol. (Ed. impr.) ; 43(10): 589-597, dic. 2020. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-197973

RESUMO

INTRODUCCIÓN: En un estudio previo demostramos que un pequeño programa de formación mejoraba los indicadores de calidad de la esofagogastroduodenoscopia (EGD) que llegaban a los estándares recomendados. Sin embargo, desconocemos el efecto de esta formación a largo plazo. El objetivo de este estudio fue valorar la calidad de las EGD después de 3años de haber realizado un programa de mejora. MATERIAL Y MÉTODOS: Estudio comparativo de 2 cohortes: EGD posteriores a un programa de formación realizado en 2016 (grupo A) y EGD en enero-marzo de 2019 (grupo B). El grupo B se dividió en 2 subgrupos: endoscopistas que habían participado en el programa de formación previo (B1) y los que no (B2). Se utilizaron los indicadores de calidad intraprocedimiento recomendados por la ASGE-ACG. RESULTADOS: Se analizaron un total de 1.236 EGD, 600 en el grupo A y 636 en el B (439 subgrupo B1 y 197 subgrupo B2). El número de exploraciones completas fue inferior en el grupo B (566 [94,3%] vs. 551 [86,6%]; p < 0,001). Se observó una disminución significativa en prácticamente todos los indicadores de calidad que, además, no alcanzaron los estándares recomendados: retroversión gástrica (96% vs. 81%; p < 0,001); protocolo de biopsias de Seattle (86% vs. 50%; p = 0,03), descripción de la lesión en la hemorragia (100% vs. 62%; p < 0,01), toma de ≥4 biopsias en sospecha de celiaquía (92,5% vs. 18%; p < 0,001), fotodocumentación de lesión (94% vs. 90%; p < 0,05). Cuando consideramos el global de la prueba (incluyendo la actuación correcta y la fotodocumentación adecuada), también se observó una disminución significativa (90,5% vs. 62%; p < 0,001). No hubo diferencias entre los subgrupos B1 y B2. CONCLUSIONES: La mejora observada en 2016 tras un programa de formación no perdura a los 3años. Es necesario hacer programas de formación continuados para mantener la calidad de la EGD por encima de los estándares recomendados


INTRODUCTION: In a previous study we demonstrated that a simple training programme improved quality indicators of Oesophagogastroduodenoscopy (OGD) achieving the recommended benchmarks. However, the long-term effect of this intervention is unknown. The aim of this study was to assess the quality of OGDs performed 3 years after of having completed a training programme. MATERIAL AND METHODS: A comparative study of 2 cohorts was designed as follows: Group A included OGDs performed in 2016 promptly after a training programme and Group B with OGDs performed from January to March 2019, this group was also divided into 2 subgroups: subgroup B1 of Endoscopists who had participated in the previous training programme and subgroup B2 of Endoscopists who had not. The intra-procedure quality indicators proposed by ASGE-ACG were used. RESULTS: A total of 1236 OGDs were analysed, 600 from Group A and 636 from Group B (439 subgroup B1 and 197 subgroup B2). The number of complete examinations was lower in Group B (566 [94.3%] vs. 551 [86.6%]; p < 0.001). A significant decrease was observed in nearly all quality indicators and they did not reach the recommended benchmarks: retroflexion in the stomach (96% vs. 81%; p < 0.001); Seattle biopsy protocol (86% vs. 50%; p = 0.03), description of the upper GI bleeding lesion (100% vs. 62%; p < 0.01), sufficient intestinal biopsy specimens (at least 4) in suspected coeliac disease (92.5% vs. 18%; p < 0.001), photo documentation of the lesion (94% vs. 90%; p < 0.05). Regarding the overall assessment of the procedure (including correct performance and adequate photo documentation), a significant decrease was also observed (90.5% vs. 62%; p < 0.001). There were no differences between subgroups B1 and B2. CONCLUSIONS: The improvement observed in 2016 after a training programme did not prevail after 3 years. In order to keep the quality of OGDs above the recommended benchmarks, it is necessary to implement continuous training programmes


Assuntos
Humanos , Indicadores de Qualidade em Assistência à Saúde/normas , Endoscopia do Sistema Digestório/métodos , Endoscopia do Sistema Digestório/normas , Estudos de Coortes , Assistência ao Paciente/normas , Indicadores de Qualidade em Assistência à Saúde/organização & administração , Assistência ao Paciente/métodos , Sociedades Médicas/normas , Estudos Prospectivos , Estudos Retrospectivos , Endoscopia/normas
11.
BMC Med ; 18(1): 255, 2020 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-32943059

RESUMO

BACKGROUND: Colon capsule endoscopy (CCE) and CT colonography (CTC) are minimally invasive techniques for colorectal cancer (CRC) screening. Our objective is to compare CCE and CTC for the identification of patients with colorectal neoplasia among participants in a CRC screening programme with positive faecal immunochemical test (FIT). Primary outcome was to compare the performance of CCE and CTC in detecting patients with neoplastic lesions. METHODS: The VICOCA study is a prospective, single-centre, randomised trial conducted from March 2014 to May 2016; 662 individuals were invited and 349 were randomised to CCE or CTC before colonoscopy. Endoscopists were blinded to the results of CCE and CTC. RESULTS: Three hundred forty-nine individuals were included: 173 in the CCE group and 176 in the CTC group. Two hundred ninety individuals agreed to participate: 147 in the CCE group and 143 in the CTC group. In the intention-to-screen analysis, sensitivity, specificity and positive and negative predictive values for the identification of individuals with colorectal neoplasia were 98.1%, 76.6%, 93.7% and 92.0% in the CCE group and 64.9%, 95.7%, 96.8% and 57.7% in the CTC group. In terms of detecting significant neoplastic lesions, the sensitivity of CCE and CTC was 96.1% and 79.3%, respectively. Detection rate for advanced colorectal neoplasm was higher in the CCE group than in the CTC group (100% and 93.1%, respectively; RR = 1.07; p = 0.08). Both CCE and CTC identified all patients with cancer. CCE detected more patients with any lesion than CTC (98.6% and 81.0%, respectively; RR = 1.22; p = 0.002). CONCLUSION: Although both techniques seem to be similar in detecting patients with advanced colorectal neoplasms, CCE is more sensitive for the detection of any neoplastic lesion. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02081742 . Registered: September 16, 2013.


Assuntos
Endoscopia por Cápsula/métodos , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Programas de Rastreamento/métodos , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
Gastroenterol Hepatol ; 43(10): 589-597, 2020 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32674879

RESUMO

INTRODUCTION: In a previous study we demonstrated that a simple training programme improved quality indicators of Oesophagogastroduodenoscopy (OGD) achieving the recommended benchmarks. However, the long-term effect of this intervention is unknown. The aim of this study was to assess the quality of OGDs performed 3 years after of having completed a training programme. MATERIAL AND METHODS: A comparative study of 2 cohorts was designed as follows: Group A included OGDs performed in 2016 promptly after a training programme and Group B with OGDs performed from January to March 2019, this group was also divided into 2 subgroups: subgroup B1 of Endoscopists who had participated in the previous training programme and subgroup B2 of Endoscopists who had not. The intra-procedure quality indicators proposed by ASGE-ACG were used. RESULTS: A total of 1236 OGDs were analysed, 600 from Group A and 636 from Group B (439 subgroup B1 and 197 subgroup B2). The number of complete examinations was lower in Group B (566 [94.3%] vs. 551 [86.6%]; p<0.001). A significant decrease was observed in nearly all quality indicators and they did not reach the recommended benchmarks: retroflexion in the stomach (96% vs. 81%; p<0.001); Seattle biopsy protocol (86% vs. 50%; p=0.03), description of the upper GI bleeding lesion (100% vs. 62%; p<0.01), sufficient intestinal biopsy specimens (at least 4) in suspected coeliac disease (92.5% vs. 18%; p<0.001), photo documentation of the lesion (94% vs. 90%; p<0.05). Regarding the overall assessment of the procedure (including correct performance and adequate photo documentation), a significant decrease was also observed (90.5% vs. 62%; p<0.001). There were no differences between subgroups B1 and B2. CONCLUSIONS: The improvement observed in 2016 after a training programme did not prevail after 3 years. In order to keep the quality of OGDs above the recommended benchmarks, it is necessary to implement continuous training programmes.


Assuntos
Benchmarking , Duodenoscopia/normas , Esofagoscopia/normas , Gastroscopia/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Biópsia/normas , Doença Celíaca/patologia , Estudos de Coortes , Duodenoscopia/educação , Duodenoscopia/estatística & dados numéricos , Esofagoscopia/educação , Esofagoscopia/estatística & dados numéricos , Hemorragia Gastrointestinal/diagnóstico por imagem , Gastroscopia/educação , Gastroscopia/estatística & dados numéricos , Humanos , Intestinos/patologia , Fotografação , Desenvolvimento de Programas , Padrões de Referência , Sociedades Médicas , Fatores de Tempo
14.
Rev. esp. enferm. dig ; 112(4): 284-289, abr. 2020. tab
Artigo em Espanhol | IBECS | ID: ibc-187507

RESUMO

INTRODUCCIÓN: existe poca evidencia científica sobre la eficacia de la dilatación endoscópica con balón (DEB) mediante enteroscopia en el tratamiento de las estenosis de intestino delgado (ID) en la enfermedad de Crohn (EC). OBJETIVO: evaluar la eficacia y la seguridad de la DEB mediante enteroscopia en pacientes con EC y estenosis en ID. MÉTODOS: estudio observacional retrospectivo en un centro de atención terciaria en pacientes con EC y estenosis de ID evaluadas por enteroTC o enteroRM. RESULTADOS: desde 2009 hasta 2019 se realizaron 205 dilataciones en 80 pacientes con EC; de ellos 17 (21,25 %) fueron pacientes con estenosis exclusivamente de ID (varones 70,6 %; edad media de 42,2 ± 14,4. El tiempo medio de seguimiento fue de 37,8 ± 28,7 meses. Se realizaron un total de 39 dilataciones. El 94,1 % eran nativas, con una longitud inferior que 5 cm y el 100 % estaban ulceradas. La tasa global de éxito técnico fue 82,4 %. El éxito clínico fue del 88,2 %. Durante el seguimiento, el 23,5 % de los sujetos requirieron de intervención quirúrgica (IQ), el 29,4 % de redilatación endoscópica y la eficacia a largo plazo fue del 76,5 %. No se produjeron complicaciones mayores. No se encontraron factores predictivos asociados con la necesidad de IQ tras la dilatación. CONCLUSIONES: las estenosis de ID pueden ser tratadas de forma segura y eficaz con DEB mediante enteroscopia asistida por balón (EAB) reduciend la necesidad de IQ a largo plazo


No disponible


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Doença de Crohn/complicações , Obstrução Intestinal/etiologia , Obstrução Intestinal/cirurgia , Intestino Delgado/patologia , Intestino Delgado/cirurgia , Endoscopia Gastrointestinal , Constrição Patológica/cirurgia , Estudos Retrospectivos , Seguimentos , Dilatação
16.
Rev Esp Enferm Dig ; 112(4): 331, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32216445

RESUMO

The novel motorized spiral rnteroscope (PowerSpiral®, Olympus) (PSE) has been recently commercialized with promising results in relation to insertion depth and time of exploration. We herewith report our first case of a total small bowel exploration with PSE.


Assuntos
Enteropatias , Laparoscopia , Endoscópios Gastrointestinais , Endoscopia Gastrointestinal , Humanos , Enteropatias/cirurgia , Intestino Delgado/diagnóstico por imagem
17.
Rev Esp Enferm Dig ; 112(4): 284-289, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32216446

RESUMO

INTRODUCTION: there is very little scientific evidence about the efficacy of endoscopic balloon dilation (EBD) performed with balloon-assisted enteroscopy (BAE) for the treatment of small bowel strictures (SBS) in Crohn's disease (CD). OBJECTIVE: to evaluate the efficacy and safety of EBD using BAE in patients with CD and SBS. METHODS: a retrospective observational study was performed in a tertiary care medical center in patients with CD and SBS, evaluated by CT enterography or MRI enterography. RESULTS: from 2009 to 2019, 205 endoscopic dilations were performed in 80 patients with CD. 17 (21.25 %) had only SBS and 70.6 % were male with a median age of 42.2 (±14.4) years. The mean follow-up was 37.8 ±28.7 months. A total of 39 dilations were performed, 94.1 % were native and less than 5cm long, all strictures were ulcerated. The overall technical success was 82.4 % and clinical success was 88.2 %. During follow-up, 23.5 % of patients required surgery and 29.4 % were re-dilated. The long-term efficacy was 76.5 % and no severe adverse events (AE) were observed. No factors were identified to predict the need for surgery after dilation. CONCLUSIONS: SBS can be safely and effectively treated with EBD using BAE, thus reducing the need for surgery in the long term.


Assuntos
Doença de Crohn , Obstrução Intestinal , Adulto , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Doença de Crohn/complicações , Doença de Crohn/diagnóstico por imagem , Dilatação , Endoscopia Gastrointestinal , Humanos , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/etiologia , Obstrução Intestinal/cirurgia , Intestino Delgado/diagnóstico por imagem , Intestino Delgado/cirurgia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
18.
Gastroenterology ; 158(4): 895-904.e1, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31520613

RESUMO

BACKGROUND & AIMS: Dye-based pancolonic chromoendoscopy is recommended for colorectal cancer surveillance in patients with Lynch syndrome. However, there is scarce evidence to support its superiority to high-definition white-light endoscopy. We performed a prospective study assess whether in the hands of high detecting colonoscopists, high-definition, white-light endoscopy is noninferior to pancolonic chromoendoscopy for detection of adenomas in patients with Lynch syndrome. METHODS: We conducted a parallel controlled study, from July 2016 through January 2018 at 14 centers in Spain of adults with pathogenic germline variants in mismatch repair genes (60% women; mean age, 47 ± 14 years) under surveillance. Patients were randomly assigned to groups that underwent high-definition white-light endoscopy (n = 128) or pancolonic chromoendoscopy (n = 128) evaluations by 24 colonoscopists who specialized in detection of colorectal lesions in high-risk patients for colorectal cancer. Adenoma detection rates (defined as the proportion of patients with at least 1 adenoma) were compared between groups, with a noninferiority margin (relative difference) of 15%. RESULTS: We found an important overlap of confidence intervals (CIs) and no significant difference in adenoma detection rates by pancolonic chromoendoscopy (34.4%; 95% CI 26.4%-43.3%) vs white-light endoscopy (28.1%; 95% CI 21.1%-36.4%; P = .28). However, pancolonic chromoendoscopy detected serrated lesions in a significantly higher proportion of patients (37.5%; 95% CI 29.5-46.1) than white-light endoscopy (23.4%; 95% CI 16.9-31.4; P = .01). However, there were no significant differences between groups in proportions of patients found to have serrated lesions of 5 mm or larger (9.4% vs 7.0%; P = .49), of proximal location (11.7% vs 10.2%; P = .68), or sessile serrated lesions (3.9% vs 5.5%; P = .55), respectively. Total procedure and withdrawal times with pancolonic chromoendoscopy (30.7 ± 12.8 minutes and 18.3 ± 7.6 minutes, respectively) were significantly longer than with white-light endoscopy (22.4 ± 8.7 minutes and 13.5 ± 5.6 minutes; P < .001). CONCLUSIONS: In a randomized parallel trial, we found that for Lynch syndrome surveillance, high-definition white-light endoscopy is not inferior to pancolonic chromoendoscopy if performed by experienced and dedicated endoscopists. ClinicalTrials.gov no: NCT02951390.


Assuntos
Adenoma/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais Hereditárias sem Polipose/complicações , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Vigilância da População/métodos , Adenoma/congênito , Adulto , Neoplasias Colorretais/congênito , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
19.
Endoscopy ; 51(7): 637-645, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31174224

RESUMO

BACKGROUND AND STUDY AIMS: Serrated polyposis syndrome (SPS) is a condition with high risk for colorectal cancer. The Endocuff device has been shown to increase adenoma detection in the general and screening population. We aimed to ascertain whether Endocuff-assisted colonoscopy increases detection of serrated lesions in comparison with standard colonoscopy during the surveillance of patients with SPS.  METHODS: In a multicenter randomized controlled study, patients who met SPS criteria I and/or III under surveillance (previous resection of all serrated lesions ≥ 4 mm) were consecutively randomly allocated 1:1 to Endocuff-assisted colonoscopy or standard colonoscopy, performed by expert endoscopists. The main outcome was the mean number of serrated lesions detected per patient. RESULTS: 122 patients (standard colonoscopy n = 60; Endocuff-assisted colonoscopy n = 62; 59 % men; mean age 60.6 (standard deviation [SD] 7.5) were included at 4 centers. Baseline variables (demographic data, SPS phenotype, colorectal cancer [CRC] history, cumulative polyps, and follow-up), cecal intubation rate, and withdrawal time were similar between groups. There was no statistically significant difference between Endocuff-assisted colonoscopy and standard colonoscopy for the mean number of serrated lesions detected per patient: 5.8 (95 % confidence interval [95 %CI] 4.4 - 7.2) and 5.0 (3.9 - 6.1), respectively (P = 0.36). There were also no differences between Endocuff-assisted and standard colonoscopy for detection of sessile serrated lesions (mean number per patient 2.5 [1.3 - 3.6] vs. 2.0 [1.1 - 3.0], P = 0.54) and adenomas (0.9 [0.5 - 1.3] vs. 0.5 [0.3 - 0.7], P = 0.12). CONCLUSION: Use of Endocuff-assisted colonoscopy did not significantly increase the number of serrated lesion detected per patient during surveillance of SPS.


Assuntos
Polipose Adenomatosa do Colo/diagnóstico , Neoplasias do Colo/diagnóstico , Colonoscopia/instrumentação , Detecção Precoce de Câncer , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
20.
Clin Transl Gastroenterol ; 10(6): e00047, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31136360

RESUMO

INTRODUCTION: Over the past 20 years, aberrant crypt foci (ACF) have emerged as potential precursors and biomarkers for colorectal cancer (CRC). However, data regarding their molecular pathogenesis, as well as their endoscopic and histological identification, remain inconsistent. METHODS: A wide cohort of ACF from 100 control subjects and 100 case patients, including patients with adenoma and CRC, were characterized for endoscopic, morphologic, and molecular features. RESULTS: We observed that among all the endoscopic features evaluated, only the number of large ACF correlated with CRC risk (P = 0.003), whereas the histological classification, as assessed by 2 different pathologists, was inconsistent and did not differ between control and case patients. Moreover, only a few APC and BRAF mutations and no microsatellite instability were detected in our samples. KRAS mutations were detected in 16.3% of ACF samples, which also exhibited increased MGMT hypermethylation. However, none of those events were found to be predictive of CRC risk. DISCUSSION: Although ACF might be preneoplastic lesions of the colon, they are not suitable biomarkers for assessing CRC progression.


Assuntos
Focos de Criptas Aberrantes/patologia , Adenoma/diagnóstico , Neoplasias Colorretais/diagnóstico , Reto/patologia , Focos de Criptas Aberrantes/genética , Adenoma/patologia , Adulto , Idoso , Biomarcadores , Estudos de Casos e Controles , Colonoscopia , Neoplasias Colorretais/patologia , Metilação de DNA , Progressão da Doença , Feminino , Humanos , Masculino , Instabilidade de Microssatélites , Pessoa de Meia-Idade , Proteínas Proto-Oncogênicas p21(ras)/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...